FURION heat pump - description

Below you can find products included in the heating system. FURION heat pump with exchanger economic heat pump photo of the FURION heat pump.

FURION with 700 l exchanger

guarantees full thermal comfort advantages

  • advantages
  • technical data
  • description

5

5-year warranty on cooling system!

  • constructed at lower costs and long-lived ground source,
  • Copeland scroll ZH - the best compressor in the market,
  • the highest COP value
  • quiet operation,
  • low operating costs
  • large volumes of DHW (min. 300 l with one heating).

Operating parameters of the FURION - COP 5,13

Measured with reference to R407C/water DZ4/W35 parameters in accordance with EN 14511 standard.

  • Spring
  • Summer
  • Autumn
  • Winter

evaporation -2C, condensation 37C, overheating 7K, subcooling 5K

Model / copeland COP consumption
kW/h / A
kW
FURION 7 /ZH21 4,91 1,67 / 3,04 8,21
FURION 9 /ZH26 4,96 2,10 / 3,99 10,40
FURION 11 /ZH30 4,92 2,43 / 4,70 12,00
FURION 14 /ZH38 4,97 2,96 / 5,76 14,70
FURION 18 / ZH45 4,98 3,51 / 6,90 17,50

 

Average measurement results from the last 3 years based on Copeland Selection Software 7.

"Lazy Jo" driver

Equipment of the FURION.

  • functions
  • description

  • programmable target temperature in a buffer, boost in case of cheap tariff on the electricity, allowable reduction, hysteresis regulation and alert thresholds.
  • weekly programme of the electricity charges tariff
  • signalisation of the excessive temperature decrease in the ground source
  • signalisation of the excessive rise in temperature in the pump output
  • high and low pressure switches control
  • compressor operating time counter
  • emergency statuses counter
  • temperature measurement on the pump output ranging from -30°C to +180°C
  • other temperature measurements ranging from -30°C to +110°C
  • measurement lines calibration
  • display of all measured temperatures
  • outputs test function allowing to check functioning of the electrical connections
  • function allowing to reinstate the default settings

Thermogolv driver

Controls operating of solar panels, fireplaces, swimming pool heating and many others - available as options.

  • advantages
  • description

  • double tariff electricity meter
  • multilingual interface,
  • cooling system temperatures monitoring
  • starts and operating hours monitoring
  • Internet capability
  • Weather-compensated control in CH circuits based on set operating state and weekly programme,
  • CH and DHW pumps management

FURION with 700 l exchanger

guarantees full thermal comfort advantages

  • advantages
  • technical data
  • description

5

5-year warranty on cooling system!

  • constructed at lower costs and long-lived ground source,
  • Copeland scroll ZH - the best compressor in the market,
  • the highest COP value
  • quiet operation,
  • low operating costs
  • large volumes of DHW (min. 300 l with one heating).

Operating parameters of the FURION - COP 5,13

Measured with reference to R407C/water DZ4/W35 parameters in accordance with EN 14511 standard.

  • Spring
  • Summer
  • Autumn
  • Winter

evaporation -2C, condensation 37C, overheating 7K, subcooling 5K

Model / copeland COP consumption
kW/h / A
kW
FURION 7 /ZH21 4,91 1,67 / 3,04 8,21
FURION 9 /ZH26 4,96 2,10 / 3,99 10,40
FURION 11 /ZH30 4,92 2,43 / 4,70 12,00
FURION 14 /ZH38 4,97 2,96 / 5,76 14,70
FURION 18 / ZH45 4,98 3,51 / 6,90 17,50

 

Average measurement results from the last 3 years based on Copeland Selection Software 7.

"Lazy Jo" driver

Equipment of the FURION.

  • functions
  • description

  • programmable target temperature in a buffer, boost in case of cheap tariff on the electricity, allowable reduction, hysteresis regulation and alert thresholds.
  • weekly programme of the electricity charges tariff
  • signalisation of the excessive temperature decrease in the ground source
  • signalisation of the excessive rise in temperature in the pump output
  • high and low pressure switches control
  • compressor operating time counter
  • emergency statuses counter
  • temperature measurement on the pump output ranging from -30°C to +180°C
  • other temperature measurements ranging from -30°C to +110°C
  • measurement lines calibration
  • display of all measured temperatures
  • outputs test function allowing to check functioning of the electrical connections
  • function allowing to reinstate the default settings

Thermogolv driver

Controls operating of solar panels, fireplaces, swimming pool heating and many others - available as options.

  • advantages
  • description

  • double tariff electricity meter
  • multilingual interface,
  • cooling system temperatures monitoring
  • starts and operating hours monitoring
  • Internet capability
  • Weather-compensated control in CH circuits based on set operating state and weekly programme,
  • CH and DHW pumps management